Print Back
Western Innovator BI Series Analog Manifolds are specifically designed to regulate and provide uninterrupted gas supply for industrial applications. Factory-set functional components are protected inside a tamper-resistant case. A green light indicates the service bank is functioning and the reserve bank is ready for service. A red light alerts the user that the unit has changed over and one or both banks are depleted (except on fuel gas units). A simple rotation of the control lever resets the unit.
BI Series Nitrous Oxide Gas Analog Manifold Systems
BI Series Nitrous Oxide Gas Analog Manifold Systems - 2
Unit of Measure
Items BI Series Nitrous Oxide Gas Analog Manifold Systems
BIHL-8-2
30 to 125 psig Internal Adjustable Line Regulator, 500 scfh with Heater Maximum Flow Rate, Nitrous Oxide Gas, and 2 Cylinders Analog Manifold System with Standard 10 in. on Center and Wall Mount
BI Series Nitrous Oxide Gas Analog Manifold Systems
BIHL-8-2-F
30 to 125 psig Internal Adjustable Line Regulator, 500 scfh with Heater Maximum Flow Rate, Nitrous Oxide Gas, and 2 Cylinders Analog Manifold System with Standard 10 in. on Center and Floor Mounted
BI Series Nitrous Oxide Gas Analog Manifold Systems
BIHL-8-4
30 to 125 psig Internal Adjustable Line Regulator, 500 scfh with Heater Maximum Flow Rate, Nitrous Oxide Gas, and 4 Cylinders Analog Manifold System with Standard 10 in. on Center and Wall Mount
BI Series Nitrous Oxide Gas Analog Manifold Systems
BIHL-8-4-F
30 to 125 psig Internal Adjustable Line Regulator, 500 scfh with Heater Maximum Flow Rate, Nitrous Oxide Gas, and 4 Cylinders Analog Manifold System with Standard 10 in. on Center and Floor Mounted
BI Series Nitrous Oxide Gas Analog Manifold Systems
BIHL-8-4-S
30 to 125 psig Internal Adjustable Line Regulator, 500 scfh with Heater Maximum Flow Rate, Nitrous Oxide Gas, and 4 Cylinders Analog Manifold System with Staggered 5 in. on Center and Wall Mount
Description N/A Western Innovator BI Series Analog Manifolds are specifically designed to regulate and provide uninterrupted gas supply for industrial applications. Factory-set functional components are protected inside a tamper-resistant case. A green light indicates the service bank is functioning and the reserve bank is ready for service. A red light alerts the user that the unit has changed over and one or both banks are depleted (except on fuel gas units). A simple rotation of the control lever resets the unit.
Field N/A Industrial
Maximum Inlet Pressure N/A 2000 psig
Maximum Flow Rate N/A With Heater: 500 scfh
Internal Adjustable Line Regulator N/A 30 to 125 psig
Manifold Outlet Thread Type N/A Male National Pipe Thread (NPT)
Manifold Outlet Size N/A 1/2 in
Relief Valve Outlet Thread Type N/A Male National Pipe Thread (MNPT)
Relief Valve Outlet Size N/A 3/4 in
Overall Manifold Length N/A 2 ft0.61 m N/A 2 ft0.61 m N/A 5 ft 5 in. 1.65 m N/A 5 ft 5 in. 1.65 m N/A 4 ft 7 in. 1.4 m
Gas Service N/A Nitrous Oxide CGA-326
Number of Cylinders N/A 2 N/A 2 N/A 4 N/A 4 N/A 4
Header Configuration N/A Standard N/A Standard N/A Standard N/A Standard N/A Staggered
Mounting N/A Wall Mount N/A Floor Mounted N/A Wall Mount N/A Floor Mounted N/A Wall Mount
Additional Information N/A
  • Automatic Analog System
  • CSA Approved Power Supply Included
  • 24" flexible stainless steel braided pigtails with check valves
  • 1/2" Brass, silver brazed headers
  • Individual header valves at each cylinder location (Units with 4 cylinders or larger-all gases except Oxygen). Oxygen units shipped with check valve outlets in place of header valves to provide added safety from heat of recompression.
  • Acetylene systems include: 300 scfh flashback arrestor and piping. Pigtails with individual flashback arrestors and check valves.
  • Fuel gas units do not include visual alarm, power supply, or any electrical components. Fuel gas alarm kits are available as an option.
  • Connects to remote alarms systems (Up to 3 amps 30 VDC or 2 amps 250 VAC)
Warning N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.