Western Innovator LC Manifolds are designed to regulate and monitor vaporized gas from cryogenic cylinders. Convenient and easy to use, the system automatically changes over when the primary cylinder bank is depleted. Simply rotate the control lever to reset the unit. A self-contained alarm system alerts the user to the system's current status. A green light indicates the service bank is functioning and the reserve bank is ready for service. A red light signals that the system has changed over and one or both banks are depleted.
LC Series Cryogenic Cylinder-Gas Withdrawal Manifold Systems
Unit of Measure
Items LC Series Cryogenic Cylinder-Gas Withdrawal Manifold Systems
LC-3-2
750 scfh Maximum Flow Rate Argon Cryogenic Cylinder-Gas Withdrawal Manifold System with Wall Mount
LC Series Cryogenic Cylinder-Gas Withdrawal Manifold Systems
LC-3-2-F
750 scfh Maximum Flow Rate Argon Cryogenic Cylinder-Gas Withdrawal Manifold System with Floor Mounted
LC Series Cryogenic Cylinder-Gas Withdrawal Manifold Systems
LC-4-2
750 scfh Maximum Flow Rate Carbon Dioxide Cryogenic Cylinder-Gas Withdrawal Manifold System with Wall Mount
LC Series Cryogenic Cylinder-Gas Withdrawal Manifold Systems
LC-4-2-F
750 scfh Maximum Flow Rate Carbon Dioxide Cryogenic Cylinder-Gas Withdrawal Manifold System with Floor Mounted
LC Series Cryogenic Cylinder-Gas Withdrawal Manifold Systems
LC-5-2
750 scfh Maximum Flow Rate Helium Cryogenic Cylinder-Gas Withdrawal Manifold System with Wall Mount
Description N/A Western Innovator LC Manifolds are designed to regulate and monitor vaporized gas from cryogenic cylinders. Convenient and easy to use, the system automatically changes over when the primary cylinder bank is depleted. Simply rotate the control lever to reset the unit. A self-contained alarm system alerts the user to the system's current status. A green light indicates the service bank is functioning and the reserve bank is ready for service. A red light signals that the system has changed over and one or both banks are depleted.
Field N/A Industrial
Maximum Inlet Pressure N/A 350 psig
Minimum Inlet Pressure N/A 125 psig
Maximum Flow Rate N/A 750 scfh
Relief Valve Dewars N/A 235 psig
Adjustable Line Regulator N/A 40 to 85 psig
Manifold Outlet Thread Type N/A Male National Pipe Thread (MNPT)
Manifold Outlet Size N/A 1/2 in
Relief Valve Outlet Thread Type N/A Male National Pipe Thread (MNPT)
Relief Valve Outlet Size N/A 1/4 in
Gas Service N/A Argon CGA-580 N/A Argon CGA-580 N/A Carbon Dioxide CGA-320 N/A Carbon Dioxide CGA-320 N/A Helium CGA-580
Number of Cylinders N/A 2
Mounting N/A Wall Mount N/A Floor Mounted N/A Wall Mount N/A Floor Mounted N/A Wall Mount
Additional Information N/A
  • Automatic Analog System
  • Gas withdrawal from Liquid Dewars
  • CSA Approved Power Source Included
  • 72" Cryogenic pigtails with check valves
  • Connects to remote alarms systems (Up to 3 amps 30 VDC or 2 amps 250 VAC)
Warning N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
Note N/A Manifold system flow is limited by the max. flow capacity of the liquid cylinder. Consult cylinder manufacturer for flow data. System flow capacity may be increased with the addition of liquid cylinders.

To maximize flow performance when more than one cylinder is used, pigtails should be used to connect the vent lines to ensure equalized cylinder pressure.