Print Back
Western Innovator LC Manifolds are designed to regulate and monitor vaporized gas from cryogenic cylinders. Convenient and easy to use, the system automatically changes over when the primary cylinder bank is depleted. Simply rotate the control lever to reset the unit. A self-contained alarm system alerts the user to the system's current status. A green light indicates the service bank is functioning and the reserve bank is ready for service. A red light signals that the system has changed overmore
Unit of Measure

Specifications

Field

Industrial

Maximum Inlet Pressure

350 psig

Minimum Inlet Pressure

125 psig

Maximum Flow Rate

750 scfh

Relief Valve Dewars

235 psig

Adjustable Line Regulator

40 to 85 psig

Manifold Outlet Thread Type

Male National Pipe Thread (MNPT)

Manifold Outlet Size

1/2 in

Relief Valve Outlet Thread Type

Male National Pipe Thread (MNPT)

Relief Valve Outlet Size

1/4 in

Gas Service

Carbon Dioxide CGA-320

Number of Cylinders

2

Mounting

Wall Mount

Additional Information

Additional Information

  • Automatic Analog System
  • Gas withdrawal from Liquid Dewars
  • CSA Approved Power Source Included
  • 72" Cryogenic pigtails with check valves
  • Connects to remote alarms systems (Up to 3 amps 30 VDC or 2 amps 250 VAC)

Prop 65

Warning

This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.

Note

Note

Manifold system flow is limited by the max. flow capacity of the liquid cylinder. Consult cylinder manufacturer for flow data. System flow capacity may be increased with the addition of liquid cylinders.

To maximize flow performance when more than one cylinder is used, pigtails should be used to connect the vent lines to ensure equalized cylinder pressure.