Print Back
Manual manifolds are designed to regulate compressed gases in high pressure cylinders (up to 3,000 psig) and are ideal for manifold applications not requiring automatic changeover from the service to the secondary bank. The MD Series duplex manifold is designed for manual changeover of 2 banks of cylinders. This system is often used as a high pressure reserve for bulk, portable bulk and gas generator systems.
Unit of Measure

Specifications

Field

N/A Industrial

Maximum Working Pressure

N/A 3000 psig

Outlet Size

N/A 1/2 in

Outlet Thread Type

N/A Male National Pipe Thread (MNPT)

Internal Adjustable Line Regulator

N/A 140 to 300 psig

Gas Service

N/A Compressed Air CGA-346

Header Configuration

N/A Standard

Number of Cylinders

N/A 14

Mounting

N/A Floor Mounted

Overall Manifold Length

N/A 12 ft 8 in. 3.86 m

Additional Information

Additional Information

N/A
  • Manual Systems
  • 24" flexible stainless steel braided pigtails with check valves. Check valve is at header end of pigtail for all gases except Oxygen.
  • Individual header valves at each cylinder location (units with 4 cylinders or larger -all gases except Oxygen)
  • Headers constructed of 1/2" brass pipe and tees
  • Optional safety kits, flash arrestor and relief valve available for Liquefied Fuel gases
  • Model RM regulator included for most gas services.
  • An alarm can be added to non fuel gas MD systems to signal changeover from service to reserve banks by adding items WME-4-9 pressure switch,WMS-1-97 adaptor, WMS-9-25C power source and BIA-3 remote A/V alarm.

Prop 65

Warning

N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.

This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.

Note

Note

N/A Only available for non-fuel gas services.