Western Innovator BI Series Analog Manifolds are specifically designed to regulate and provide uninterrupted gas supply for industrial applications. Factory-set functional components are protected inside a tamper-resistant case. A green light indicates the service bank is functioning and the reserve bank is ready for service. A red light alerts the user that the unit has changed over and one or both banks are depleted (except on fuel gas units). A simple rotation of the control lever resets the unit.
Unit of Measure
Items |
/Asset/2.jpg BI-5-2 30 to 125 psig Internal Adjustable Line Regulator, 300 scfh Maximum Flow Rate, Helium Gas, and 2 Cylinders Analog Manifold System with Standard 10 in. on Center and Wall Mount |
/Asset/2.jpg BI-5-2-F 30 to 125 psig Internal Adjustable Line Regulator, 300 scfh Maximum Flow Rate, Helium Gas, and 2 Cylinders Analog Manifold System with Standard 10 in. on Center and Floor Mounted |
/Asset/2.jpg BI-5-4 30 to 125 psig Internal Adjustable Line Regulator, 300 scfh Maximum Flow Rate, Helium Gas, and 4 Cylinders Analog Manifold System with Standard 10 in. on Center and Wall Mount |
/Asset/2.jpg BI-5-4-F 30 to 125 psig Internal Adjustable Line Regulator, 300 scfh Maximum Flow Rate, Helium Gas, and 4 Cylinders Analog Manifold System with Standard 10 in. on Center and Floor Mounted |
/Asset/2.jpg BI-5-4-S 30 to 125 psig Internal Adjustable Line Regulator, 300 scfh Maximum Flow Rate, Helium Gas, and 4 Cylinders Analog Manifold System with Staggered 5 in. on Center and Wall Mount |
|||||
Description | N/A Western Innovator BI Series Analog Manifolds are specifically designed to regulate and provide uninterrupted gas supply for industrial applications. Factory-set functional components are protected inside a tamper-resistant case. A green light indicates the service bank is functioning and the reserve bank is ready for service. A red light alerts the user that the unit has changed over and one or both banks are depleted (except on fuel gas units). A simple rotation of the control lever resets the unit. | |||||||||
Field | N/A Industrial | |||||||||
Maximum Inlet Pressure | N/A 3000 psig | |||||||||
Maximum Flow Rate | N/A 1200 scfh | |||||||||
Internal Adjustable Line Regulator | N/A 30 to 125 psig | |||||||||
Manifold Outlet Thread Type | N/A Male National Pipe Thread (NPT) | |||||||||
Manifold Outlet Size | N/A 1/2 in | |||||||||
Relief Valve Outlet Thread Type | N/A Male National Pipe Thread (MNPT) | |||||||||
Relief Valve Outlet Size | N/A 3/4 in | |||||||||
Overall Manifold Length | N/A 2 ft0.61 m | N/A 2 ft0.61 m | N/A 5 ft 5 in. 1.65 m | N/A 5 ft 5 in. 1.65 m | N/A 4 ft 7 in. 1.4 m | |||||
Gas Service | N/A Helium CGA-580 | |||||||||
Number of Cylinders | N/A 2 | N/A 2 | N/A 4 | N/A 4 | N/A 4 | |||||
Header Configuration | N/A Standard | N/A Standard | N/A Standard | N/A Standard | N/A Staggered | |||||
Mounting | N/A Wall Mount | N/A Floor Mounted | N/A Wall Mount | N/A Floor Mounted | N/A Wall Mount | |||||
Additional Information |
N/A
|
|||||||||
Warning | N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. | |||||||||
|