Western Innovator LA manifolds are designed for applications using cryogenic cylinders as a primary gas source, but usage is insufficient to warrant liquid as a reserve. This LA series manifold will automatically switch over from service to reserve bank without any interruption of service. Line pressure will remain constant within a variation of ± 2% throughout the changeover cycle. An alarm can be added to signal changeover from service to reserve banks by adding items: WME-4-9 pressure switch, WMS-1-97 orificed adaptor, WMS-9-25C power supply box and BIA-3 remote audio visual alarm.
Unit of Measure
Items
LA Series Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold Systems

750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Standard 10 in. on Center and Wall Mount

LA Series Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold Systems

750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Standard 10 in. on Center and Floor Mounted

LA Series Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold Systems

750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Staggered 5 in. on Center and Wall Mount

LA Series Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold Systems

750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Staggered 5 in. on Center and Floor Mounted

LA Series Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold Systems

750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Vertical crossover 10 in. on Center and Wall Mount
Description N/A Western Innovator LA manifolds are designed for applications using cryogenic cylinders as a primary gas source, but usage is insufficient to warrant liquid as a reserve. This LA series manifold will automatically switch over from service to reserve bank without any interruption of service. Line pressure will remain constant within a variation of ± 2% throughout the changeover cycle. An alarm can be added to signal changeover from service to reserve banks by adding items: WME-4-9 pressure switch, WMS-1-97 orificed adaptor, WMS-9-25C power supply box and BIA-3 remote audio visual alarm.
Field N/A Industrial
Maximum Working Pressure N/A 3000 psig
Minimum Inlet Pressure N/A 125 psig
Maximum Flow Rate N/A 750 scfh
Adjustable Cryogenic Line Regulator N/A 40 to 85 psig
Manifold Outlet Thread Type N/A Male National Pipe Thread (NPT)
Manifold Outlet Size N/A 1/2 in
Gas Service N/A Argon CGA-580
Number of Cylinders N/A 2
Header Configuration N/A Standard N/A Standard N/A Staggered N/A Staggered N/A Vertical Crossover
Mounting N/A Wall Mount N/A Floor Mounted N/A Wall Mount N/A Floor Mounted N/A Wall Mount
Additional Information N/A
  • Automatic L x HP System
  • Gas withdrawal from Liquid Dewars
  • Maximum working pressure for high pressure reserve system: 3000 psig
  • 24" flexible stainless steel braided pigtails with check valves, for high pressure bank
  • Cryogenic side includes 72" cryogenic pigtails with check valves (nylon inner core with polyester braid). Maximum working pressure 1375 psig.
  • Inlet pressures from each liquid cylinder must be the same
  • Individual header valves at each cylinder location (units with 2 cylinders or larger-all gases except Oxygen). Oxygen units shipped with check valve outlets in place of header valves to provide added safety from heat of recompression.
  • 1/2" Brass, silver brazed headers
Warning N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.