SDLA Series Manual Changeover Manifold Systems
Industrial Systems
Western Innovator SDLA Manual Changeover Manifolds are designed for applications requiring gas withdrawal from cryogenic cylinders. The SDLA manifolds are designed for use with up to 4 cylinders, 2 per bank, and can flow from both banks or one bank can be kept in reserve. An alarm can be added to signal when your primary bank is nearly depleted.
Unit of Measure
Items |
/Asset/a1052.jpg SDLA-3-4 750 scfh Maximum Flow Rate Argon Manual Changeover Manifold System with Wall Mount |
/Asset/a1052.jpg SDLA-3-4-F 750 scfh Maximum Flow Rate Argon Manual Changeover Manifold System with Floor Mounted |
/Asset/a1052.jpg SDLA-4-4 750 scfh Maximum Flow Rate Carbon Dioxide Manual Changeover Manifold System with Wall Mount |
/Asset/a1052.jpg SDLA-4-4-F 750 scfh Maximum Flow Rate Carbon Dioxide Manual Changeover Manifold System with Floor Mounted |
/Asset/a1052.jpg SDLA-5-4 750 scfh Maximum Flow Rate Helium Manual Changeover Manifold System with Wall Mount |
|||||
Description | N/A Western Innovator SDLA Manual Changeover Manifolds are designed for applications requiring gas withdrawal from cryogenic cylinders. The SDLA manifolds are designed for use with up to 4 cylinders, 2 per bank, and can flow from both banks or one bank can be kept in reserve. An alarm can be added to signal when your primary bank is nearly depleted. | |||||||||
Field | N/A Industrial | |||||||||
Minimum Inlet Pressure | N/A 125 psig | |||||||||
Maximum Inlet Pressure | N/A 350 psig | |||||||||
Adjustable Line Regulator | N/A 40 to 100 psig | |||||||||
Maximum Flow Rate | N/A 750 scfh | |||||||||
Relief Valve Dewars | N/A 235 psig | |||||||||
Manifold Outlet Size | N/A 1/2 in | |||||||||
Manifold Outlet Thread Type | N/A Male National Pipe Thread (NPT) | |||||||||
Line Relief Valve Outlet Size | N/A 1/2 in | |||||||||
Line Relief Valve Outlet Thread Type | N/A Female National Pipe Thread (FNPT) | |||||||||
Gas Service | N/A Argon CGA-580 | N/A Argon CGA-580 | N/A Carbon Dioxide CGA-320 | N/A Carbon Dioxide CGA-320 | N/A Helium CGA-580 | |||||
Mounting | N/A Wall Mount | N/A Floor Mounted | N/A Wall Mount | N/A Floor Mounted | N/A Wall Mount | |||||
Number of Cylinders | N/A 4 | |||||||||
Additional Information |
N/A
|
|||||||||
Warning | N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. | |||||||||
Note | N/A To maximize flow performance when more than one cylinder is used, pigtails should be used to connect the vent lines to ensure equalized cylinder pressure. | |||||||||
|