LA Series Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold Systems
Industrial Systems
Western Innovator LA manifolds are designed for applications using cryogenic cylinders as a primary gas source, but usage is insufficient to warrant liquid as a reserve. This LA series manifold will automatically switch over from service to reserve bank without any interruption of service. Line pressure will remain constant within a variation of ± 2% throughout the changeover cycle. An alarm can be added to signal changeover from service to reserve banks by adding items: WME-4-9 pressure switch, WMS-1-97 orificed adaptor, WMS-9-25C power supply box and BIA-3 remote audio visual alarm.
Unit of Measure
| Items |
/Asset/a1040.jpg LA-3-2 750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Standard 10 in. on Center and Wall Mount |
/Asset/a1040.jpg LA-3-2-F 750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Standard 10 in. on Center and Floor Mounted |
/Asset/a1040.jpg LA-3-2-S 750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Staggered 5 in. on Center and Wall Mount |
/Asset/a1040.jpg LA-3-2-S-F 750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Staggered 5 in. on Center and Floor Mounted |
/Asset/a1040.jpg LA-3-2-V 750 scfh Maximum Flow Rate, 40 to 85 psig Internal Adjustable Line Regulator, and Argon Cryogenic Cylinder-Gas Withdrawal X High Pressure Manifold System with Vertical crossover 10 in. on Center and Wall Mount |
|||||
| Description | N/A Western Innovator LA manifolds are designed for applications using cryogenic cylinders as a primary gas source, but usage is insufficient to warrant liquid as a reserve. This LA series manifold will automatically switch over from service to reserve bank without any interruption of service. Line pressure will remain constant within a variation of ± 2% throughout the changeover cycle. An alarm can be added to signal changeover from service to reserve banks by adding items: WME-4-9 pressure switch, WMS-1-97 orificed adaptor, WMS-9-25C power supply box and BIA-3 remote audio visual alarm. | |||||||||
| Field | N/A Industrial | |||||||||
| Maximum Working Pressure | N/A 3000 psig | |||||||||
| Minimum Inlet Pressure | N/A 125 psig | |||||||||
| Maximum Flow Rate | N/A 750 scfh | |||||||||
| Adjustable Cryogenic Line Regulator | N/A 40 to 85 psig | |||||||||
| Manifold Outlet Thread Type | N/A Male National Pipe Thread (NPT) | |||||||||
| Manifold Outlet Size | N/A 1/2 in | |||||||||
| Gas Service | N/A Argon CGA-580 | |||||||||
| Number of Cylinders | N/A 2 | |||||||||
| Header Configuration | N/A Standard | N/A Standard | N/A Staggered | N/A Staggered | N/A Vertical Crossover | |||||
| Mounting | N/A Wall Mount | N/A Floor Mounted | N/A Wall Mount | N/A Floor Mounted | N/A Wall Mount | |||||
| Additional Information |
N/A
|
|||||||||
| Warning | N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. | |||||||||
|
|
||||||||||