Check Valves
Industrial Products
Reverse Flow Check Valves
For torch and regulator applications, Western Check Valves guard against danger caused by plugged tips, over pressurizing or incorrect startup procedures. Proper Check Valve installation helps prevent accidents caused by gases mixing in hoses, regulators or cylinders.
For torch and regulator applications, Western Check Valves guard against danger caused by plugged tips, over pressurizing or incorrect startup procedures. Proper Check Valve installation helps prevent accidents caused by gases mixing in hoses, regulators or cylinders.
Unit of Measure
Items |
![]() WE-63 Torch Style Check Valve Set |
![]() CV-7R Oxygen Gas Right Hand B-Size Male to B-Size Female Nut Torch Style Check Valve |
![]() CV-8L Fuel Gas Left Hand B-Size Male to B-Size Female Nut Torch Style Check Valve |
![]() CV-30R Oxygen Gas Right Hand B-Size Female Nut to B-Size Male Regulator Adaptor Model Check Valve |
![]() CV-31L Fuel Gas Left Hand B-Size Female Nut to B-Size Male Regulator Adaptor Model Check Valve |
|||||
Description |
N/A
Torch Model, A-Size (3/8"-24) A one-piece, compact unit designed for A-Size applications. Mounts to torch to prevent reverse flow at point of origin. Torch Style - Set CV-A9 & CV-A10. |
N/A
Torch Model, B-Size (9/16"-18) Mounts easily on torch, is readily seen and can be removed for periodic testing. Flows cut up to 12" steel plate or handle heating tips (1200 SCFH at 50 PSIG). Stops reverse flow at point of origin. Oxygen RH, B-Size Male to B-Size Female Nut, to 125 PSIG (800kPa). |
N/A
Torch Model, B-Size (9/16"-18) Mounts easily on torch, is readily seen and can be removed for periodic testing. Flows cut up to 12" steel plate or handle heating tips (1200 SCFH at 50 PSIG). Stops reverse flow at point of origin. Fuel Gas LH, B-Size Male to B-Size Female Nut, to 50 PSIG (345 kPa). |
N/A
Regulator Bushing Adaptor Model, B-Size (9/16"-18) Easily mounts on outlet bushing of any regulator having a B-Size outlet. This model has the same flow capacity as the torch - type (1200 SCFH at 50 PSIG) when installed on a regulator. The Check Valve is to easy to see and is less subject to contamination, abuse and damage. Oxygen RH, B-Size Female Nut to B-Size Male, to 125 PSIG (800kPa). |
N/A
Regulator Bushing Adaptor Model, B-Size (9/16"-18) Easily mounts on outlet bushing of any regulator having a B-Size outlet. This model has the same flow capacity as the torch - type (1200 SCFH at 50 PSIG) when installed on a regulator. The Check Valve is to easy to see and is less subject to contamination, abuse and damage. Fuel Gas LH, B-Size F Nut to B-Size Male, to 50 PSIG (345 kPa). |
|||||
Field | N/A Industrial | |||||||||
Model | N/A Torch | N/A Torch | N/A Torch | N/A Regulator Bushing Adapter | N/A Regulator Bushing Adapter | |||||
Thread Size | N/A 3/8 in | N/A 9/16 in | N/A 9/16 in | N/A 9/16 in | N/A 9/16 in | |||||
Number of Threads per Inch | N/A 24 | N/A 18 | N/A 18 | N/A 18 | N/A 18 | |||||
Maximum Working Pressure | N/A | N/A 125 psig | N/A 50 psig | N/A 125 psig | N/A 50 psig | |||||
Gas Service | N/A | N/A CGA-022 | N/A CGA-023 | N/A CGA-022 | N/A CGA-023 | |||||
Gas | N/A | N/A Oxygen | N/A Fuel Gases | N/A Oxygen | N/A Fuel Gases | |||||
Material | N/A | |||||||||
Valve Seat Material | N/A | N/A Buna-N™ | N/A Buna-N™ | N/A Buna-N™ | N/A Buna-N™ | |||||
Check Valve Flow Specifications Charts | N/A Flow curves presented here are based on air at 70 ºF. To convert flows of other gases, multiply by the appropriate conversion factor listed on instruction sheets included with all check valves. | |||||||||
Additional Information |
N/A
Western's reverse flow Check Valves meet or exceed CGA and OSHA requirements (Pamphlet CGA-E2) and feature:
|
|||||||||
Warning | N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. | |||||||||
Note | N/A Check valves do not stop flashbacks. |
N/A
Check Valves Do Not Stop Flashbacks. UL Listed |
N/A
Check Valves Do Not Stop Flashbacks. UL Listed |
N/A
Check Valves Do Not Stop Flashbacks. UL Listed |
N/A
Check Valves Do Not Stop Flashbacks. UL Listed |
|||||
|