Western Innovator AGM2 Manifolds are designed and manufactured according to NFPA-99 2012 safety and performance requirements. Easy-to-read analog gauges indicate the line and individual bank pressures. A green light means the service bank is functioning and the reserve bank is ready for service. A red light alerts the user that one or both banks are depleted. A simple rotation of the control lever resets the unit.
Unit of Measure
Items
AGM2 Series Carbon Dioxide Gas Manifold Systems

500 scfh with Heater Maximum Flow Rate, Carbon Dioxide Gas, and 4 Cylinders Manifold System with Standard 10 in. on Center and Wall mount

AGM2 Series Carbon Dioxide Gas Manifold Systems

500 scfh with Heater Maximum Flow Rate, Carbon Dioxide Gas, and 4 Cylinders Manifold System with Standard 10 in. on Center and Floor Mounted

AGM2 Series Carbon Dioxide Gas Manifold Systems

500 scfh with Heater Maximum Flow Rate, Carbon Dioxide Gas, and 4 Cylinders Manifold System with Vertical crossover 10 in. on Center and Wall mount

AGM2 Series Carbon Dioxide Gas Manifold Systems

500 scfh with Heater Maximum Flow Rate, Carbon Dioxide Gas, and 4 Cylinders Manifold System with Vertical crossover 10 in. on Center and Floor Mounted

AGM2 Series Carbon Dioxide Gas Manifold Systems

500 scfh with Heater Maximum Flow Rate, Carbon Dioxide Gas, and 4 Cylinders Manifold System with Staggered 5 in. on Center and Wall mount
Description N/A Western Innovator AGM2 Manifolds are designed and manufactured according to NFPA-99 2012 safety and performance requirements. Easy-to-read analog gauges indicate the line and individual bank pressures. A green light means the service bank is functioning and the reserve bank is ready for service. A red light alerts the user that one or both banks are depleted. A simple rotation of the control lever resets the unit.
Field N/A Medical
Maximum Inlet Pressure N/A 2000 psig
Maximum Flow Rate N/A With Heater: 500 scfh
Internal Adjustable Dual Line Regulators N/A 30 to 55 psig
Manifold Outlet Size N/A 1/2 in
Manifold Outlet Thread Type N/A Male National Pipe Thread (NPT)
Relief Valve Outlet Size N/A 1/2 in
Relief Valve Outlet Thread Type N/A Male National Pipe Thread (MNPT)
Overall Manifold Length N/A 5 ft 11 in. 1.80 m N/A 5 ft 11 in. 1.80 m N/A 4 ft 3 in. 1.30 m N/A 4 ft 3 in. 1.30 m N/A 5 ft 1 in. 1.55 m
Gas Service N/A Carbon Dioxide CGA-320
Number of Cylinders N/A 4
Header Configuration N/A Standard N/A Standard N/A Vertical Crossover N/A Vertical Crossover N/A Staggered
Mounting N/A Wall Mount N/A Floor Mounted N/A Wall Mount N/A Floor Mounted N/A Wall Mount
Additional Information N/A
  • NFPA Compliant, Automatic Analog System
  • CSA Approved Power Supply included
  • Oxygen Pigtails: NFPA 99 compliant, rigid copper, with check valves
  • Other Gas Pigtails: NFPA 99 compliant, 24" flexible stainless steel with check valves
  • 1/2" Brass, silver brazed headers
  • Digital readout can display psig, kPa or Bar
  • Connects to remote alarms systems (Up to 3 amps 30 VDC or 2 amps 250 VAC)
Warning N/A This product can expose you to lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.